GlucoMen
areo B-Ketone Sensor

Description
In vitro diagnostic medical device.
Sensors for self-monitoring of ketonemia with the GlucoMen areo 2K instrument.
They are sensors indicated for the quantitative determination of beta-hydroxybutyrate (BOHB or beta-ketone) in fresh capillary whole blood.
Use the GlucoMen areo Beta-Ketone Sensor only with the GlucoMen areo 2K meter.
The GlucoMen areo 2K system is designed for home monitoring and self-monitoring of blood glucose and beta-ketone levels and can also be used in hospital settings by healthcare professionals.
The system is not intended for use in the diagnosis or screening of DKA or for use in neonates.
Do not change your therapy based on the results of your blood ketone tests without first consulting your doctor or healthcare professional.

General characteristics
Measurement of blood ketonemia beta-hydroxybutyrate (BOHB or beta-ketone) in the blood
Enzyme composition (per cm2 of a test strip for measuring blood ketonemia) - D-3-hydroxybutyrate dehydrogenase ( Pseudomonas sp. ) 1.5% w/w
- coenzyme (NAD+), 0.7% w/w
- redox mediator: 1,10-phenanthroline-5,6-dione, 20.0% w/w
- non-reactive substances: 77.8% w/w
Unit of measurement
Beta-ketone mmol/L (not modifiable)
Measuring range
Beta-ketone 0.1-8.0 mmol/L
Response time
Beta-ketone 8 seconds
Sample volume
Beta-ketone 0.8 microL
Acceptable hematocrit range
Beta-ketone automatically compensates the measurement based on the hematocrit in the range 20-60%
Calibration and traceability The GlucoMen areo 2K system was calibrated to plasma reference values ​​determined using a Stanbio Beta-Hydroxybutyrate LiquiColor procedure, Procedure No. 2440 (Stanbio Laboratory, 1261 North Main Street, Boerne, Texas 78006). The analyzer using the Stanbio kit (secondary reference measurement procedure) was calibrated with a set of beta-hydroxybutyrate-containing standards (primary calibrators) prepared gravimetrically at Stanbio Laboratory.
Sample fresh capillary whole blood
Sensor coding not requested
Hygiene automatic ejection of the test strip via dedicated ejection button
Sampling automatic blood sample aspiration by capillary action
Operating environment
Beta-ketone Temperature range: 10-40°C
relative humidity: <85%

How to use
1. Insert a new GlucoMen areo Beta-Ketone Sensor (light purple) into the test strip port. The drop symbol will start flashing on the display and the ketone symbol "Keth" will appear in the lower left corner. If nothing appears on the display, remove the sensor, reinsert it into the port, and wait for the drop symbol to start flashing.
2. Hold the tip of the sensor in contact with the drop of blood until the control window fills. You will hear a beep (if enabled) and the display will show a countdown.
3. Read the test results. A beep will announce the test result with the ketone symbol "Keth" appearing on the screen. The symbol will flash until the meter turns off.
4. To remove the sensor, press the eject button. The instrument will turn off.
Do not use the GlucoMen areo Beta-Ketone Sensor to test samples from alternative sites: use only fresh capillary blood from the fingertip.

Warnings
The GlucoMen areo Beta-Ketone Sensor is for in vitro diagnostic use only (for external use only).
Results may be incorrect if the patient is dehydrated, severely hypertensive, in shock, or in a hyperosmolar state.
Do not test patients in critical health conditions.
If the blood ketone test results are not consistent with your perceived health status even though you have followed all the instructions in the GlucoMen areo 2K meter user manual, contact your doctor or healthcare professional.
Never make significant changes to your diabetes management plan without first talking to your doctor.
Keep the instrument, sensors, and other system components out of the reach of children. Small parts may pose a choking hazard.
Handle the sensors with clean, dry hands.
Dispose of used lancets (needles) and sensors according to local regulations.
Handling blood can be dangerous; use extreme caution when handling blood, sensors, lancets (needles), and the meter.

Conservation
Store the aluminum blister pack of sensors at 4-30°C; do not freeze or refrigerate.
Avoid exposure to humidity, heat, and direct sunlight. Do not use the sensors beyond the expiration date as it may cause incorrect results.
Check the expiry date on the aluminum blister.
GlucoMen areo Beta-Ketone Sensor strips are individually packaged in aluminum blisters, with a shelf life of 18 months from the date of manufacture.

Format
Pack of 10 pieces.

Cod. 48530

GLUCOMEN

Glucomen Areo B-Ketone Sensor 10-Piece Ketone Measurement Strips

Glucomen Areo B-Ketone Sensor 10-Piece Ketone Measurement Strips

MINSAN code: 938766565
Previous price: €19,33
Regular price €19,33
Regular price €25,40 Sale price €19,33
-23% Sold out
Tax included. Shipping calculated at checkout.
View full details

Product images are purely indicative and may not be fully representative of the packaging and product features, as they may vary in color, size, or content. Any decorations, gift wrapping, and items included in the images for product presentation purposes will not be shipped with orders. Product names, ingredients, and percentages indicated in the descriptions are purely indicative and may be subject to change or updates by the manufacturers. Due to the impossibility of updating these updates in real time, the photos and technical information of the products listed on farmaInnovation.it may differ from those shown on the label or otherwise disclosed by the manufacturers. The only identifying element is the MINSAN (Ministry of Health) code. Farmacia Barni, farmainnovation.it , does not guarantee the accuracy and timeliness of the information published and declines all responsibility for any errors, omissions, or failure to update it. farmainnovation.it assumes no responsibility for damages of any kind that may arise from accessing the published information.