SOFARMAPIU'
RAPID PHARYNGEAL TEST STREPTO A SOFARMAPIU' DETECTION OF STREPTOCOCCUS A ANTIGEN ON THORARYGEAL SWAB BY PROFESSIONAL IMMUNOCHROMATOGRAPHY 10 PIECES
RAPID PHARYNGEAL TEST STREPTO A SOFARMAPIU' DETECTION OF STREPTOCOCCUS A ANTIGEN ON THORARYGEAL SWAB BY PROFESSIONAL IMMUNOCHROMATOGRAPHY 10 PIECES
Secure payment
Discreet and sanitized package
Fast and safe shipping
Description
Description
TEST
STREPTOCOCCUS
Rapid test for the detection of group A streptococcus in throat infections.
How to use
Sample collection
Use only the sterile reagents and swabs provided in the kit.
Collect the sample using the sterile throat swab provided in the kit. Swab the posterior pharynx, tonsils, and other inflamed areas.
Avoid contact of the swab with the tongue, cheeks and teeth.
The test should preferably be performed immediately after sample collection. Samples can be stored in a clean, dry plastic tube at room temperature for up to 8 hours or at 2-8°C for up to 72 hours. Swabs containing modified Stuart or Amies transport medium can also be used with this product.
If you wish to perform a culture, gently rotate the swab tip on a group A selective blood plate (GAS) before using the swab with the Streptococcal Rapid Test Device (Throat Swab).
Test procedure
Bring the test card, reagents, throat swab and/or controls to room temperature (15-30°C) before testing.
Remove the card from the sealed pouch and use it immediately.
Holding the Reagent 1 bottle upright, add 4 drops (approximately 240 mcl) to a sample extraction tube. Reagent 1 is red. Holding the Reagent 2 bottle upright, add 4 drops (approximately 160 mcl) to the tube. Reagent 2 is colorless. Mix the solution by gently swirling the tube. Adding Reagent 2 to Reagent 1 changes the color of the solution from red to yellow.
Immediately add the throat swab to the yellow solution in the tube. Swirl the swab in the tube 15 times. Leave the swab in the tube for 1 minute. Then, press the swab into the tube and squeeze the bottom of the tube while removing the swab. Discard the swab.
Insert the dropper tip into the top of the test tube. Place the test card on a clean, flat surface. Add 3 drops of solution (100 mcl) to the sample well (S) and start the timer.
Wait for the red band(s) to appear.
Read the result after 5 minutes. Do not interpret the result after 10 minutes.
Interpretation of the results
Positive: Two distinct red lines appear, one in the control region (C) and the other in the test region (T). A positive result indicates that Streptococcus A has been detected in the sample.
Negative: A red line appears in the control region (C). No red or pink line appears in the test region (T). A negative result indicates that Strep A antigen is not present in the specimen or is present below the detectable threshold of the test. The patient's specimen should be cultured to confirm the absence of Strep A infection. If clinical symptoms are inconsistent with the results, another specimen should be cultured.
Invalid: No band appears. The most likely reasons for the control band not appearing are insufficient sample volume or incorrect procedure. Review the procedure and repeat the test with a new card. If the problem persists, discontinue use of the kit and contact your local distributor.
Warnings
If swallowed: If you feel unwell, call a poison control center or doctor.
In case of eye contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor.
Do not freeze. Do not use after the expiration date.
For professional in vitro diagnostic use only.
Do not eat, drink, or smoke in the area where specimens and kits are handled.
Handle all samples as if potentially infectious. Observe appropriate precautions against microbiological hazards at all stages of the analysis and follow standard procedures for proper sample disposal.
When analyzing samples, wear protective clothing: lab coat, disposable gloves, and eye protection.
Humidity and temperature can negatively affect the results.
Do not use the test if the pouch is damaged.
Reagent 2 contains an acidic solution. If the solution comes into contact with skin or eyes, rinse with plenty of water.
Positive and negative controls contain Proclin300 as a preservative.
Do not interchange reagent bottle caps.
Do not interchange the caps of the external control solution bottles.
The Streptococcal A rapid test device (throat swab) is for in vitro diagnostic use only. The test should be used to detect Streptococcal A antigen in throat swabs only. It cannot determine the quantitative value or percentage of increase in Streptococcal A antigen status.
This test only indicates the presence of Strep A antigen in the specimen due to both viable and non-viable Group A Streptococcus bacteria.
A negative result must be confirmed by culture. A negative result may be due to an inadequate or lower than detectable Strep A antigen concentration in the throat swab.
The sterile swabs provided with this test must be used for specimen collection. Other swabs have not been validated for this test.
Excessive blood or mucus on the swab can interfere with the test results and cause a false positive. Avoid contact of the swab with the tongue, cheeks, teeth, and any oral areas with open wounds when the sample is collected.
As with all diagnostic tests, results must be interpreted in light of the patient's overall clinical picture.
Conservation
Store at room temperature or in the refrigerator (2-30°C).
Shelf life when packaged intact: 16 months.
Format
Kit contents:
- reagent 1 for Strepto A (2 M sodium nitrite)*;
- reagent 2 for Strepto A (0.027 M citric acid);
- card;
- sterile swabs;
- methodical;
- dropper dispenser;
- test tubes for sample extraction;
- test tube/reagent support;
- positive control for Strepto A (Non-viable Strepto A Proclin 300 0.01%);
- negative control for Strepto A (non-viable Strepto C Proclin 300 0.01%).
*Keep out of reach of children. Wear gloves and eye and face protection.
Cod. 70773
SOFARMAPIU'
RAPID PHARYNGEAL TEST STREPTO A SOFARMAPIU' DETECTION OF STREPTOCOCCUS A ANTIGEN ON THORARYGEAL SWAB BY PROFESSIONAL IMMUNOCHROMATOGRAPHY 10 PIECES
RAPID PHARYNGEAL TEST STREPTO A SOFARMAPIU' DETECTION OF STREPTOCOCCUS A ANTIGEN ON THORARYGEAL SWAB BY PROFESSIONAL IMMUNOCHROMATOGRAPHY 10 PIECES
Couldn't load pickup availability

Is this your first order?
We offer a hassle-free return policy, so you can shop with confidence. Fast and reliable shipping ensures your products arrive directly to your door. And don't worry about privacy : your data is safe with us. We're here to make your online shopping a stress-free and convenient experience.
Sign up for our newsletter. We only send useful stuff. We promise 😉
Product images are purely indicative and may not be fully representative of the packaging and product features, as they may vary in color, size, or content. Any decorations, gift wrapping, and items included in the images for product presentation purposes will not be shipped with orders. Product names, ingredients, and percentages indicated in the descriptions are purely indicative and may be subject to change or updates by the manufacturers. Due to the impossibility of updating these updates in real time, the photos and technical information of the products listed on farmaInnovation.it may differ from those shown on the label or otherwise disclosed by the manufacturers. The only identifying element is the MINSAN (Ministry of Health) code. Farmacia Barni, farmainnovation.it , does not guarantee the accuracy and timeliness of the information published and declines all responsibility for any errors, omissions, or failure to update it. farmainnovation.it assumes no responsibility for damages of any kind that may arise from accessing the published information.